Chamber Furnaces with Brick Insulation or Fiber Insulation
Chamber Furnaces with Brick Insulation or Fiber Insulation
Chamber Furnaces with Brick Insulation or Fiber Insulation
Chamber Furnaces with Brick Insulation or Fiber Insulation
Chamber Furnaces with Brick Insulation or Fiber Insulation
Chamber Furnaces with Brick Insulation or Fiber Insulation

Share:


Chamber Furnaces with Brick Insulation or Fiber Insulation

Chamber furnaces LH 15/12 - LF 120/14 are suitable for many different glass applications. They are available with either a robust insulation of light refractory bricks (LH models) or with a combination insulation of refractory bricks in the corners and low heat storage, quickly cooling fiber material (LF models). With a wide variety of optional equipment, these chamber furnaces can be adapted optimally and individually to suit your processes.

  • Tmax 1200 °C, 1300 °C, or 1400 °C
  • Dual shell housing with rear ventilation, provides for low shell temperatures
  • High furnace chamber with five-sided heating for very good temperature uniformity
  • Heating elements on support tubes ensure free heat radiation and a long service life
  • Controller mounted on furnace door and removable for comfortable operation
  • Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor
  • LH models: multi-layered insulation of light refractory bricks and special backup insulation
  • LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Motorized exhaust air flap
  • Freely adjustable air inlet integrated in furnace floor
  • Base included
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Controller B500 (5 prgrams with each 4 segments)
Additional Equipment
  • Parallel swinging door (user protected from heat radiation)
  • Lift door with electro-mechanic linear drive for opening when hot
  • Cooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume. Both operating modes can be switched on and off for different segments by means of the extra function of the controller.
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Stainless steel exhaust hood as interface to customer’s exhaust system
  • Process control and documentation via VCD software package for monitoring, documentation and control
  • Parallel swinging door (user protected from heat radiation)
  • Lift door with electro-mechanic linear drive for opening when hot
  • Cooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume. Both operating modes can be switched on and off for different segments by means of the extra function of the controller.
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Stainless steel exhaust hood as interface to customer’s exhaust system
  • Process control and documentation via VCD software package for monitoring, documentation and control
Model Tmax Inner dimensions in mm Volume Outer dimensions1 in mm Connected Electrical Weight
  in °C w d h in l W D H load in kW connection in kg
LH 15/12 1200 250 250 250 15 680 860 1230 5.0 3-phase2 170
LH 30/12 1200 320 320 320 30 710 930 1290 7.0 3-phase2 200
LH 60/12 1200 400 400 400 60 790 1080 1370 8.0 3-phase 300
LH 120/12 1200 500 500 500 120 890 1180 1470 12.0 3-phase 410
LH 216/12 1200 600 600 600 216 990 1280 1590 20.0 3-phase 450
                       
LH 15/13 1300 250 250 250 15 680 860 1230 7.0 3-phase2 170
LH 30/13 1300 320 320 320 30 710 930 1290 8.0 3-phase2 200
LH 60/13 1300 400 400 400 60 790 1080 1370 11.0 3-phase 300
LH 120/13 1300 500 500 500 120 890 1180 1470 15.0 3-phase 410
LH 216/13 1300 600 600 600 216 990 1280 1590 22.0 3-phase 460
                       
LH 15/14 1400 250 250 250 15 680 860 1230 8.0 3-phase2 170
LH 30/14 1400 320 320 320 30 710 930 1290 10.0 3-phase2 200
LH 60/14 1400 400 400 400 60 790 1080 1370 12.0 3-phase 300
LH 120/14 1400 500 500 500 120 890 1180 1470 18.0 3-phase 410
LH 216/14 1400 600 600 600 216 990 1280 1590 26.0 3-phase 470
                       
LF 15/13 1300 250 250 250 15 680 860 1230 7.0 3-phase2 150
LF 30/13 1300 320 320 320 30 710 930 1290 8.0 3-phase2 180
LF 60/13 1300 400 400 400 60 790 1080 1370 11.0 3-phase 270
LF 120/13 1300 500 500 500 120 890 1180 1470 15.0 3-phase 370
                       
LF 15/14 1400 250 250 250 15 680 860 1230 8.0 3-phase2 150
LF 30/14 1400 320 320 320 30 710 930 1290 10.0 3-phase2 180
LF 60/14 1400 400 400 400 60 790 1080 1370 12.0 3-phase 270
LF 120/14 1400 500 500 500 120 890 1180 1470 18.0 3-phase 370
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
2Heating only between two phases

 