Heating cabinets are ideal for processes in the low temperature range up to max. 150 °C, such as for drying, preheating molds and tools or tempering and curing plastics. They have a compact design and are especially suitable for large charges. They are heated with a separate heating unit that is generally located behind the heating cabinet.
- Tmax 150 °C
- Separate, electric heating unit, consisting of heater register, air circulation system, fresh air inlet and exhaust air outlet
- Powerful, turbulent air flow inside the oven
- Atmosphere exchange via open fresh air inlet and exhaust air outlet
- Temperature uniformity according to DIN 17052-1 up to +/− 6 °C
- Wall structure with 50 mm insulation for a surface temperature Tamb.+ 25 °C, slightly higher near the door. The oven thus complies with ISO 13732-1.
- Floor-level charging without floor insulation
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
- Interior with galvanized steel plate
- Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
- Defined application within the constraints of the operating instructions
- Controller with touch operation B500 (5 programs with 4 segments each)
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
- Freeware NTEdit for convenient program input via ExcelTM for WindowsTM on the PC
- Freeware NTGraph for evaluation and documention of firings using ExcelTM for WindowsTM on the PC
- MyNabertherm App for online monitoring of the firing on mobile devices for free download
- ADDITIONAL EQUIPMENT
- Steel plate to protect the base against mechanical damage
- Floor insulation, also with drive-in tracks or frame
- Charging trolleys in different designs to allow for charge assembly outside the heating cabinet
- Window in the oven door and interior lighting
- Thermocouple inlets in various sizes
- Cooling system with fan
- Process control and documentation via VCD software package for monitoring, documentation and control
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions1 in mm | Heating power | Connected load | ||||
---|---|---|---|---|---|---|---|---|---|---|
°C | b | d | h | in l | W | D | H | in kW | in kW | |
WK 4500 | 150 | 1500 | 1500 | 2000 | 4500 | 1980 | 3110 | 2500 | 18 | 21 |
WK 6000 | 150 | 1500 | 2000 | 2000 | 6000 | 1980 | 3610 | 2500 | 18 | 21 |
WK 6001 | 150 | 2000 | 1500 | 2000 | 6000 | 2480 | 3110 | 2500 | 18 | 21 |
WK 7500 | 150 | 2500 | 1500 | 2000 | 7500 | 2980 | 3110 | 2500 | 27 | 30 |
WK 8000 | 150 | 2000 | 2000 | 2000 | 8000 | 2460 | 3570 | 2500 | 27 | 32 |
WK 10000 | 150 | 2000 | 2500 | 2000 | 10000 | 2460 | 4070 | 2500 | 45 | 50 |
WK 10001 | 150 | 2500 | 2000 | 2000 | 10000 | 2960 | 3570 | 2500 | 45 | 50 |
WK 12000 | 150 | 2000 | 3000 | 2000 | 12000 | 2460 | 4570 | 2500 | 45 | 50 |
WK 15000 | 150 | 2500 | 3000 | 2000 | 15000 | 2900 | 4720 | 2500 | 54 | 62 |
WK 17500 | 150 | 2500 | 3500 | 2000 | 17500 | 2900 | 5220 | 2500 | 54 | 62 |